More information?
Joost van der Poel
Accountmanager
Cable terminations
Cables with a conductor insulation screen must have a correct field finish in the cable termination. Straight end fittings, in heat shrinkage or cold shrinkage, correct fittings tailored to the ambient conditions and voltage class are supplied from stock. The connection is shielded by an insulated boot. With high voltage, other factors play a role in determining the correct fitting, self-supporting or supported, with or without a surge diverter. We provide advice on cables and their use.
You can read more about cable terminations here:
NKT | Cable terminations |
SOTCable terminations | Roll springs |
TCCable terminations | Braided wire |
Elcon Megarad | Shrink fittings |
Heat shrinkable cable terminations | Connector fittings |
Elbow cable connectors
Elbow cable connectors for plug-in applications on A-B-C-D and F Bushings according to EN50180 and EN50181. Available as a single and a linkable version for parallel connection and/or as a surge diverter. Easy to demonstrate that it is voltage-free. Ask for extensive documentation or tailor-made advice.
You can read more about plug-in cable terminations/connectors here:
NKT
Connex
Plug-in cable connectors for 3kV max. 1250A to 550kV max. 4000A for use in transformers, switchgear. They are fully touch-proof and upon request available as an “offshore” version. These are used for a wide range of extreme conditions, including offshore HVDC platforms. Our Connex system provides you with many advantages, such as quick installation in the event of a disaster, high-voltage emergency systems. Testing of the installations is simplified by reducing the number of system disassembly operations. Configurations as cable terminations, through joints as well as T-joints are available so whatever your requirement, there is always a solution. For detailed advice, please contact our account manager.
Read more about Connex here:
Pfisterer
High-voltage accessories
Customisation is important when connecting the high voltage system. The fittings are determined and produced for each system and cable. Installation must be carried out by certified personnel, which we will provide for you.
With regard to cable terminations and joints, there are a number of options that we will discuss with you in advance before the customised work is delivered:
- How will they be connected to the system?
- Who is responsible for the installation?
- What is the pollution class?
- How and where will they be installed?
- Are there any fibreglass conductors present?
- Is the application of cross-bonding required?
After answering these questions, Batenburg Energietechniek can swiftly deliver the required materials to your desired location. Request detailed advice.
Read more about High-voltage accessories here:
Pfisterer
Connector joints
Cable joints for the medium voltage are available in many shapes and sizes, for example for renewing XLPE cables, transitions from GPLK to XLPE and transitions between 3 and 1 phase cables.
Because of differences in the cables, several accessories are required, and we will provide advice on which materials are suitable for this purpose.
We offer cable joints for all voltage levels and based on different techniques, we can offer the right joint for every cable.
Read more about our connector joints here:
MV joints | LV joints |
NKT | ISO-elektra |
Sliding joints | Hard shell joints |
Cold shrinkable joints | |
Elcon Megarad | |
Heat shrinkable joints |
Shrink tubes
Shrink tubes are used to create mechanical and insulating protection. We have solutions for shrink tubes with or without glue, thick, medium and thin walled. Our black shrink tubes are UV resistant and our shrink tubes are available in all kinds of colors. The shrink tubes can withstand a dielectric strength of more than 25kV per mm.
Read more about our shrink tubes:
Elcon Megarad
With cables and installations, the connection determines your reliability, safety and quality. Cable connections can be found at all occurring voltage levels, in direct and alternating current (DC-AC). If it is about connecting a house to the energy net with the “ring clamp" with more than 50 years of experience or if it is the plug-in connection “Connex” that is used on Offshore wind farms to the high-voltage connections up to 380kV.
A reliable connection is created by cooperation of the correct contact technique, suitable cable fittings, cable preparation with the right tools and assembly according to the current instructions. With or without certified technicians.
Customization
A connection is custom-made, conductors and conditions differ per make and application. Batenburg Energietechniek gives you the guidance to establish a reliable connection. Call or email our specialists for personal and situational advice.
Training
Would you like to become a certified technician for our products? Or do you want more information about our products? Ask our account manager for advice.